for up to 500 contact pins, working area 191.5 x 172 mm



Dimensions: 28 x 33 x 23 cm, (w, d, h; dimensions without lever), weight: 9 kg
  • max. 500 spring contact pins
  • Contacting from top and bottom with optional upper exchange plate
  • Dual-stage contacting – optional
  • Also for double-sided loaded PCBs
  • Exchangeable retention box with 12 retention pins, adjusted as needed
  • Power stop for softened closing
  • Very long durability
  • Little operation force
  • High quality ball bearings at the fulcrums
  • Ergonomic

This universal manual test fixture for electronic PCBs offers very low repeat cost for further types of PCBs. This fixture is designed for max. 500 spring contact pins and is operated with one hand. In 1 minute the unit is modified for a new type of PCB.
As we think ergonomics is very important we use a lid which opens very wide so that the test item can be inserted and removed very fast and comfortably. This guarantees short handling times and little fatigue of the operator. In the final stage when parallelism is important, a sophisticated kinematics ensures that the retention box with its retention pins presses the test item down with 100 % parallelism. The high-quality ball bearings grant a long-lasting use free of maintenance. One million and more contacting are common. A little maintenance work ensures further millions of contacting.

Working Method
The test item is contacted by the spring contacts on the plate (8 mm thick). It is very important that the test item is guided with precision guiding (e.g. REINHARDT-reference pin type 3). When inserted, the test item is only a little above the spring contact pins. When the lever of the retention lid is pulled down, the retention pins press the test item onto the bed-of-nails. Now the spring contacts contact e.g. test pads, solder joints or vias without solder resist coating.

Bed-of-Nails – Exchange Plate
Our exchange plates (bed of nails) are drawers. The basic fixture is connected to the exchange plate by plugging a number of 64-/96-way multi-way connectors once. This is why the times for changing component types are very short (typically 1 minute).

Retention Box
The basic version of a fixture comes with an exchangeable box with 12 retention pins. With knurled screws, both the retention pins and the 4 receiver rails of the retention box can be adjusted as required by the resp. item to be tested. You therefore only buy the box once – this reduces your testing cost.
Additional retention boxes (options) can be exchanged fast and comfortably if you use them for a special test item and do not want to adjust the retention pins especially for this test item. The upper exchange plate is only inserted and can easily be changed for an optional box for solder defects or polarity test.

Contacting from Top and Bottom
For contacting from top and bottom, an optional upper plate with contact pins from above and pin-polarity test probes can be used instead of the retention box. REINHARDT-fixture systems are highly parallel. This is important for contacting the electronic PCBs precisely from top and bottom.

Housings
Fixture Type 127 comes with a closed metal housing with an SR08VG-interface on the rear. Different multi-way connectors of the  DIN 41612 series can be plugged into this interface, i. e. you can use high-voltage connectors or connectors with high-current contacts or HF-contacts. 2 64-way multi-way connectors DIN41612 are standard equipment of the SR08VG-interface.

As the universal exchange plates can be changed easily, you only need new plates for a new test fixture. This is why this fixture system is so cost-effective. The upper retention exchange box (incl. 12 retention pins, mounted to 4 receiver profiles) can easily be exchanged for another box for the universal fixture or for an optional box for solder defects or polarity test.

Size of the exchange plate: 217.6 x 230 x 8 mm






* All prices are valid in Germany and the European Community and are without taxes, transport and packing. IE & OE – Specifications subject to change without prior notice.


ATS-MFT 770


Multifunktionstestsysteme für In-Circuit Test ICT und Funktionstest FKT von elektronischen Flachbaugruppen, Modulen und Geräten


Search

Search Term

Enquiry Quotation

Your quotation enquiry is empty

Login

Your Username
Your Password:



> Register
> Forgot Password

ATS-MFT 770


Multifunktionstestsysteme für In-Circuit Test ICT und Funktionstest FKT von elektronischen Flachbaugruppen, Modulen und Geräten